Radio Base Stations of PCCW


Agent/Owner: PCCW

Consultant: Troika Engineering Limited

Background:
PCCW intended to expand and improve their services of mobile cell sites by erecting new radio base stations on new sites and modifying existing equipment or antenna on existing sites.

Troika's Works:

  • AP declaration for the proposed Radio Base Stations of whether they are classified as exempted or not exempted building works to comply with the One Stop Application Procedure (OSAP) requirements for outdoor and indoor coverage systems.

  • Providing Structural Calculation for equipment and antennas with sketches.

  • Providing detailed drawing.

  • For New Private Sites / Existing Private Sites requiring or not requiring statutory submission to BD, acting as AP/RSE to prepare full submission to BD for approval and consent including reporting work completion to BD / to apply Minor Works and provide Safety Supervision Plan with adequate Technical Competent Person (TCP) to comply with Building Ordinance respectively.

  • For Government Property Agent (GPA) / Non-GPA-other Government Departments or agencies, acting as AP/RSE to prepare full submission to GPA and relevant Government Departments / to prepare full submission to Non-GPA-other Government Departments or agencies respectively.

  • For HKHA/Link submission to Independent Checking Unit (ICU) requiring / not requiring formal approval, acting as AP/RSE to prepare full submission to ICU for approval and consent / to apply Minor Works and provide Safety Supervision Plan with adequate Technical Competent Person (TCP) to comply with Building Ordinance respectively.

  • For MTRC/HKT Sites and existing sites requiring / not requiring statutory submission to BD, acting as AP/RSE to prepare full submission to BD for approval and consent including reporting work completion to BD / to apply Minor Works and provide Safety Supervision Plan with adequate Technical Competent Person (TCP) to comply with Building Ordinance respectively.

  • Preparing Structural Appraisal of existing site with existing design calculation and drawings.

  • Inspecting the site construction and endorsing as-built documents submitted by contractors after the site work.

  • Providing Fire Service Inspection for Occupation Permit approval granted from relevant Government Department.